Your most important room deserves proper engineering

Your servers, storage, firewalls and core switches are the heart of your IT. If the room they live in overheats, loses power or floods, your whole business stops. Yet in many companies the “server room” is a storage cupboard with a domestic air conditioner, a power strip and no lock.

In Egypt, heat makes this especially risky. Equipment generates heat constantly, and if cooling fails on a summer weekend, temperatures can rise past safe limits within an hour. Power fluctuations and outages, dust, and water from AC units add further risk.

ITZone designs and builds server rooms and comms rooms that protect your equipment properly. We calculate the heat and power load, choose the right cooling and UPS, plan the racks and cable routes, add fire suppression and access control, and install sensors that alert us before anything goes wrong. Whether you need a single-rack comms room or a multi-rack data room, we build it to last and document it fully.

Is this you?

Tick what sounds familiar. We’ll include it with your quote request.

What you get

Room design and layout

Rack positions, hot and cold aisles, clearances for maintenance, cable routes and space for growth.

Precision cooling

Cooling sized to your actual heat load, with redundancy so one unit failing doesn’t cause overheating. For small rooms this may be dedicated split units with controllers; for larger rooms, in-row or precision cooling.

UPS and power

UPS systems sized for safe runtime, dedicated circuits, power distribution units in each rack and connection to the building generator where available.

Fire detection and suppression

Clean-agent gas suppression that puts out fires without damaging electronics, installed by approved fire-safety partners.

Access control and CCTV

Card or biometric access with an entry log, and cameras covering the room.

Environmental monitoring

Sensors for temperature, humidity, water leaks, smoke and power, with alerts to our engineers 24/7.

What is a server room?

A server room is a dedicated, secured space that houses servers, storage and network equipment with controlled power, cooling, security and connectivity. It can be a single-rack comms room or a multi-rack equipment room serving a whole building. The principles are the same at every size: keep equipment within safe temperature and humidity, provide clean and continuous power, protect it from fire and unauthorised access, and make it easy to maintain and expand.

Many businesses now use a hybrid approach: a small, well-built server room on site for local systems, combined with cloud hosting in Egypt for critical workloads. We help you decide what belongs where.

Server room requirements checklist

RequirementWhy it matters
Dedicated, lockable roomControls access and keeps equipment separate from staff areas
Cooling sized to heat load, with redundancyPrevents overheating if one unit fails
Temperature and humidity controlRecommended operating range roughly 18–27 °C
UPS with enough runtimeRides through short outages and allows safe shutdown
Fire detection and clean-agent suppressionStops fires without destroying equipment
No water pipes above equipmentAvoids leak damage
Raised floor or overhead cable traysKeeps cabling organised and airflow clear
Environmental monitoring with alertsDetects problems out of hours
Access control and entry logSecurity and audit evidence
Labelled racks and documentationFaster maintenance and troubleshooting

How we build your server room

  1. Survey and load calculation

    We assess the room, the equipment you have and plan to add, and calculate heat and power requirements.

  2. Design and quote

    Layout drawings, equipment list, and a fixed quote, including any civil works, electrical and fire-safety items.

  3. Build

    Electrical works, cooling installation, racks, containment, cabling, fire suppression and access control, coordinated with your landlord and contractors.

  4. Commissioning and testing

    We test cooling failover, UPS runtime, alarms and monitoring before moving equipment in.

  5. Migration and handover

    Equipment is moved in a planned window, then you receive drawings, test results and a maintenance plan.

Not sure what you need?

We’ll audit your IT for free and tell you.

Options

Small server roomComms / data roomLarge multi-rack room
Racks1–22–66+
CoolingDedicated split unitsIn-row / precisionPrecision with redundancy
UPSRack UPSModular UPSRedundant UPS
Fire suppressionOptional / recommended✓✓

Maintenance after handover

Cooling units, UPS batteries and fire systems all need regular maintenance. UPS batteries typically need replacing every three to five years, and cooling filters need cleaning regularly in Egypt’s dusty conditions. We offer a maintenance plan covering inspections, battery tests, alarm tests and 24/7 environmental monitoring.

Case study

A trading company in 10th of Ramadan City moved servers from a store room into a new two-rack server room with redundant cooling and UPS, ending heat-related failures.

Server Room Build questions, answered

What is a server room?

A dedicated, secured space that houses servers, storage and network equipment with controlled power, cooling, security and connectivity.

What are the requirements for a server room?

Stable temperature and humidity, reliable power with UPS, fire detection and suppression, physical security, cable management and monitoring.

Should we build a server room or move to the cloud?

It depends on your applications, data rules and costs. Many businesses use a small server room plus cloud hosting. See Cloud Hosting

Do you handle fire suppression approvals?

We coordinate with approved fire-system contractors for the required authority approvals.

Can you upgrade our existing server room without downtime?

Usually yes. We phase the work, install new cooling and power alongside the old, and move equipment in short planned windows.

How long does a server room build take?

A small room typically takes two to four weeks; larger rooms with civil works take longer.

What temperature should a server room be?

Most equipment manufacturers and industry guidance recommend an inlet temperature of roughly 18–27 °C with controlled humidity. We set alarms well before the upper limit so there is time to act.

How long should the UPS last?

Long enough to ride through short outages and, if power doesn’t return, to shut systems down safely or wait for the generator. For most offices that means ten to thirty minutes at full load.